Home » Air Release Valves at High Points in Low-Pressure Lines

Air Release Valves at High Points in Low-Pressure Lines

A practical guide to air at high points: why low-pressure lines trap it, how release and air/vacuum valves divide the work, and where each belongs on a farm main.
Empty channel runs at bench height in a bright house, the high line an airlock can stall above the rows

Air is the cheapest fault to prevent and the hardest to diagnose. It arrives dissolved in the water, comes out of solution where pressure falls, and rises to the highest point it can reach — on a farm main, a crest between two houses or the top of a riser. A small air release valve at that crest costs less than a metre of trench. Without one, a pocket that would be a nuisance at 3 bar expands at 0.3 bar until it occupies most of the section. Flow falls, one section starves, and the pump gauge looks normal.

Why Air Collects at High Points

Air enters a line in three ways: dissolved in the raw water, entrained at the suction, or admitted when a section drains and refills. Once inside, buoyancy takes over. Bubbles rise against the flow, and wherever the pipe has a local crest, they accumulate faster than the velocity can sweep them over the top.

Low pressure makes it worse in two directions. A pocket expands as pressure falls, so the same mass of air blocks a much larger share of the bore at 0.3 bar than at 3 bar. And the velocity in a low-pressure main is usually modest, which is exactly the condition that lets a pocket sit still.

Two Valves, Two Jobs

Hydraulic practice separates the duties, and mixing them up is the most common specification error on a farm.

Valve typeOrificeWhat it doesWhere it belongs
Automatic air releaseSmall, 1–3 mmBleeds air continuously while the line is pressurisedEvery local high point on a working main
Air and vacuum valveLarge, 25–100 mmAdmits air as a line drains, expels it fast as a line fillsHigh points, long horizontal runs, filter and tank tops
Combination valveBoth in one bodyDoes both jobs at one tappingWhere only one tapping is practical
Manual petcockSmallVents when an operator opens itCommissioning and temporary lines only
Degassing at the sumpNot a valveLets air escape before the pump drawsWhere entrainment is the main source

A small release valve will not clear a line that has emptied; it will hiss for an hour and pass almost nothing. A large air/vacuum valve alone will not remove the fine bubbles that come out of solution during the day. Most farms need both duties, sometimes in one body.

Where to Place Them

Empty channel runs at bench height in a bright house, the high line an airlock can stall above the rows

Placement follows the profile, not the drawing grid. Five positions cover most installations:

  • Every local crest on the supply main, including the top of each riser where a buried line comes up into a house.
  • The discharge header at its highest point, downstream of the pump and after the check valve.
  • Long flat runs at intervals of roughly 30–60 m where the profile is undulating, since air will find the shallowest sag or crest between them.
  • Filter outlets, where air released by a pressure drop through the element accumulates.
  • The end of a dead-ended branch, which is a high point by default.

Each valve needs an isolation valve beneath it and a small drain above the floor, so it can be serviced without draining the main. A valve fitted directly to the pipe with no isolation is a valve nobody ever cleans. Routing rules that keep crests to a minimum in the first place are in pipework runs and manifold layout.

What an Airlock Looks Like From the Control Room

The signature is a section that under-delivers while the pump appears healthy. Pressure at the discharge is normal or slightly high, flow at the station meter is below expectation, and one zone or one end of a zone is dry. Opening another zone sometimes restores flow briefly, because the higher velocity drags the pocket over the crest.

Three checks separate an airlock from its lookalikes:

  1. Compare gauge readings either side of the suspect section. A pocket produces a small, erratic differential that moves when flow changes; a blocked filter produces a steady differential that grows over days.
  2. Listen at the crest. A working release valve ticks and hisses. Silence at a known high point during refill is the clue.
  3. Check the pump suction. Cavitation noise at the pump, not at the crest, points to the suction side rather than to trapped air downstream.

Pressure shock and pump-side air each have their own failure patterns, covered in the articles on water hammer in hydroponics and pump cavitation and suction faults.

Sizing the Air and Vacuum Side

The large-orifice valve is sized by how fast the line fills and drains, not by the pipe diameter. Two planning rules make the choice straightforward.

  • Filling: keep the fill velocity at or below about 0.3 m/s. At that rate a valve sized for the pipe’s nominal bore will pass the displaced air comfortably; fill faster and the valve becomes the restriction.
  • Draining: the valve must admit air at least as fast as the drain can empty the line, or the section collapses under vacuum. A drain that empties a 100 m main in ten minutes needs an admitting capacity matched to that rate.

The small release orifice is sized differently again: it must pass the volume of air that comes out of solution plus any small ingress, which on a warm recirculating system is usually modest. Oversizing the small orifice wastes water; undersizing it leaves the pocket in place.

Commissioning and the Annual Habit

Fine misting inside a greenhouse bay, air and water mixing in the head space a vent has to clear

Most air problems are created on the day a line is first filled and never revisited. The sequence that avoids them is slow and boring: fill at low velocity with every release valve open, vent until the ticking stops, then bring the line to working pressure and re-vent at the highest point once flow is established.

After that, the valves need a yearly intervention rather than a replacement schedule. Scale and biofilm block small orifices, floats stick, and a valve that has been weeping for a season looks exactly like one that is working. Open each valve, clean the orifice, test the float, and record the date. On a site with twenty crests, that is an afternoon a year.

Air control is a layout decision before it is a valve purchase. Put the tappings where the profile puts the crests, give each one an isolation valve, and the air release valve becomes a maintenance item instead of a mystery.

FAQs About Air Release Valves

How many air release valves does a farm main need?

One at every local high point, plus one at the pump discharge header and one at the end of any dead-ended branch. On an undulating long run, add one every 30–60 m rather than trusting a single crest.

Will an air release valve fix a line that will not fill?

Only if air is the obstruction and the valve has enough orifice. A small release valve cannot pass the volume displaced by a filling main; that job belongs to an air and vacuum valve.

Why does flow improve when we open another zone?

Higher total flow raises velocity and drags the pocket over the crest. It is a useful diagnostic and a poor permanent solution: the pocket returns as soon as the zone closes.

Can air pockets damage a pump?

Downstream pockets mostly cost flow. Air reaching the suction side causes cavitation, which damages impellers and seals, and that is a separate fault with a separate fix.

Do buried lines need air valves too?

Yes, at the crests and at each riser. A buried profile is rarely as smooth as the drawing suggests, and a pocket under a path is expensive to reach later.

Related Reading

Next Step: What to Send for a Quotation

Valves are cheap; tappings are not. Decide the positions while the pipework is still being drawn.

Specifying a main or a riser? For RFQ or project consultation, send: a profile sketch showing crests, risers and drain points; pipe diameters and material; working pressure and maximum flow; fill and drain procedure planned; number of high points; whether combination valves are preferred; isolation and drain requirements; fluid temperature range; spare valve allowance; delivery schedule; and the budget band. G AND N FORTUNE LIMITED supplies air release, air/vacuum and combination valves together with the manifolds and fittings they mount on.

Table of Contents

Planning a Hydroponic Project?

Need help choosing a growing system or equipment? Tell us about your project requirements.

Discuss Your Project
CONTINUE EXPLORING
Back to News
KEEP EXPLORING

Related Articles

Continue exploring practical insights on hydroponic systems, crop growing, equipment selection, and commercial farm projects.

View All Articles
Pipe rail with its fittings above a bucket bench, the supply side a new line flushes before planting
A project-engineering view of new-line flushing and balancing: what construction leaves inside pipes, flush velocities and durations that actually clean, pressure testing, and how to
Gutter rows stepping down a house alongside a walkway, the fall a drain collection line mirrors
A project-engineering view of drain collection layout: floor and pipe slope planning ranges, gully placement, the fall gravity return lines need, and the ways these
TURN KNOWLEDGE INTO ACTION

Have a Hydroponic Project in Mind?

From growing system selection to equipment planning, share your project requirements with G&N Fortune and explore suitable solutions for your needs.

Prefer email? info@gnhydroponic.com

Request a Project Quote

Tell us about your requirements. Our team will review your inquiry and contact you about the next steps.